Product specifications
8 Issue 1, November 2003 61181113L2-5A
7. PROVISIONING
Through management access via the Total Access 3000
System Controller Unit (SCU), as detailed in the SCU
Control Port Operation-HDSL2 section, the provi-
sioning settings can be viewed and manipulated.
Table 4 lists the available provisioning options and the
factory default settings.
Table 4. Provisioning Options
Provisioning Option Option Settings Default Settings
1. DSX-1 Line Build Out 0-133 ft.
133-266 ft.
266-399 ft.
399-533 ft.
533-655 ft.
0 to 133 ft.
2. DSX-1/DS1 Line Code B8ZS, AMI B8ZS
3. DSX-1/DS1 Framing SF, ESF, Unframed, Auto ESF
4. Force Frame Conversion Disabled, Enabled Disabled
5. Smartjack Loopback Disabled, Enabled Enabled
6. Loopback Time Out None, 120 Min 120 Minutes
7. Latching Loopback Mode T1 (Disabled), FT1 (Enabled) T1 (Disabled)
8. DS1 Tx Level 0 dB, –7.5 dB, –15 dB 0 dB
9. Span Power Enabled, Disabled Enabled
10. Customer Loss Indicator AIS, Loopback, AIS/CI AIS/CI
11. Performance Reporting Messages None, SPRM, NPRM, AUTO (both) AUTO
12. Loop Attenuation Alarm Threshold 0 (Disabled), 1-99 dB 30 dB
13. SNR Margin Alarm Threshold 0 (Disabled), 1-15 dB 04 dB
14. Remote Provisioning Disabled, Enabled Enabled
15. Service State
1
In Service, Out of Service-
Unassigned, Out of Service-
Maintenance
Out of Service-Maintenance
16. Network Source DSX, MUX A, MUX B, Auto MUX DSX
17. External Alarms Enabled, Disabled Disabled
18. Auto In Service Disabled, Enabled Enabled
19. Auto IS Startup Period 1 hour, 4 hours, 8 hours, 24 hours 4 hours
20. Auto IS Off Period 1 hour, 4 hours, 8 hours, 24 hours 8 hours
1
The Service State defaults to Out of Service-Maintenance. This setting allows active connections to the DSX or MUX interface; however,
no alarms will be generated. The In Service setting allows full functioning connections to DSX or MUX interfaces. Out of Service-