Product specifications

61181113L2-5A Issue 1, November 2003 25
The Troubleshooting screen (Figure 35) compiles infor-
mation received from all facilities and equipment in the
circuit and presents them in both Real-Time and 7-Day
historical format.
The Troubleshooting Guidance screen (Figure 36)
option (accessed from the
Troubleshooting screen)
analyzes this information and makes repair recommen-
dations.
Figure 35. Troubleshooting Screen
Figure 36. Troubleshooting Guidance Screen
Shelf: 1 Slot: 14 Total Access System 10/28/03 08:59
Unacknowledged Alarms: INFO
Circuit ID:
Troubleshooting
For HELP based on detected problems, select Troubleshooting Guidance from the
list below. If further assistance is needed, contact ADTRAN Tech Support.
Hours: Normal 7am - 7pm CST 1. Troubleshooting Guidance
Emergency 7 days x 24 hours 2. General Information
Phone: 800.726.8663 / 888.873.HDSL
Fax: 256.963.6217
Shelf: 1 Slot: 14 Total Access System 10/28/03 08:59
Unacknowledged Alarms: INFO
Facility DC Open
- A DC Open condition is often caused by a lack of current flow on the DSL
loops. The condition should be resolved when an H2TUR (or H4R) is installed.
- If open is not due to absence of equipment, verify wiring in the H2TUR (or
H4R) housing. If still open, troubleshoot facility wiring for an open circuit.
Looking toward the CO, you should see approximately 190 volts across T/T1 and
R/R1 at any point. Also, if HDSL2 equipment is connected you should see a short
on both pairs in both directions. If not an open circuit still exists.
- If wiring and shelf OK, connect H2TUR at the frame and verify DSL sync can be
achieved. If not, replace the H2TUC and H2TUR one at a time to identify the
problem.