Product specifications

2 Issue 1, November 2003 61181113L2-5A
Features
The basic features of the HDSL2 Total Access 3000
H2TU-C, (P/N 1181113L2) include the following:
Auto In Service
Bit Error Rate Testing (BERT)
Flash Upgrade
Troubleshooting Guidance
•TScan
These and other features will be discussed in the
practice.
The H2TU-C contains an onboard fuse. If the fuse
opens, it supplies a –48 VDC voltage to the fuse alarm
bus, and all front panel indicators turn off. The fuse is
not designed to be replaced in the field.
The H2TU-C uses a DC-to-DC converter to derive its
internal logic and span powering voltages from the
–48 VDC office supply. Span-powering voltages meet
all requirements of Class A2 voltages as specified by
Bellcore GR-1089-CORE.
System power and alarm bus connections are made
through the backplane of the Total Access shelf. DSX1
and HDSL2 signals are connected through the 64-pin
shelf connectors related to each individual slot.
TScan
This unit is equipped to support the
TScan™ feature,
which provides data retrieval and diagnostic capabil-
ities for remote management of DS1 circuits.
TScan
allows provisioning, performance, and event history
information to be retrieved by the test center via the
Facility Data Link (FDL). In addition,
TScan can be
used to determine the nature and location of faults on
DS1 trouble circuits.
TScan is accessible only through
the remote test center.
NOTE
For implementation of
TScan please contact
your local ADTRAN sales representative.
A patent-pending single-ended diagnostic routine
residing on a host server at the central test facility,
TScan issues commands and retrieves data via FDL
from the H2TU-C.
TScan performs the following functions (see Figure 2):
Detection and location of an open, one or both
conductors
Detection and location of a short between Tip and
Ring
Detection and location of a ground fault from either
or both conductors
Detection of foreign voltage
H2TU-C Self Diagnostics
Ability to remotely detect the presence or absence
of a ground connection in the remote mount.
TScan allows operators to integrate these capabilities
across multiple computing platforms with existing
operating systems.
Figure 2. TScan Diagnostic Capabilities
Auto In Service
The Total Access 3000 H2TU-C supports the Auto In-
Service feature that will automatically change the
service state of the line card from
Out-of-service
Maintenance (OOS-MA)
to In-Service and vice versa
based on DSL loop synchronization and/or DSX-1/DS1
alarm presence.
This and other features are discussed in more detail in
the SCU Control Port Operation-HDSL2 section.
Bit Error Rate Testing (BERT)
This Total Access HDSL2 unit has the capability to
initiate and record BERT via the Craft Access Terminal
menus. It features eight timed and user-selectable data
patterns as well as the ability to insert errors.
Compliance
Table 2 shows the compliance codes for the Total
Access 3000 H2TU-C. The Total Access 3000 H2TU-C
is NRTL listed to the applicable UL standards. The
Total Access 3000 H2TU-C is to be installed in a
restricted access location and in a Type “B” or “E”
enclosure only.
C
CO Outside Plant Facilities
R
Open on either conductor
CR
Open on both conductors
CR
Short between T&R
CR
Short to ground from eith
er
or both conductors
X
X
X