Product specifications
18 Issue 1, November 2003 61181113L2-5A
Selecting number “4” from the BERT menu will display
the first of the
BERT Test Functions, the Time-out
Screen
(Figure 22). The time out can run for a specific
duration by entering the hours and/or minutes, or can
run indefinitely by entering 00:00, per the note on the
screen. With no test running, selection “
5” from the
BERT menu will allow the tester to toggle the test signal
in the opposite direction (from customer to network and
vice versa).
When “
1” is pressed to start the test, option “5” changes
to “
Inject Bit Errors” as in Figure 23. This allows the
tester to generate errors from this test origination point
to validate the test results.
Figure 22. BERT Test Functions
Selection 4, Enter Test Time Out
Figure 23. BERT Inject Errors Screen
Shelf: 1 Slot: 18 Total Access System 10/28/03 08:59
Unacknowledged Alarms: MAJOR INFO
Circuit ID:
CUSTOMER Timeout Screen
Test Timeout(Hr:Min) = 02:00
----------------------------
1. Change Timeout 02:00
02:00
*NOTE: When timeout is set to 00:00, the
test will run indefinitely.
Selection:
Shelf: 1 Slot: 14 Total Access System 10/28/03 08:59
Unacknowledged Alarms: INFO
Circuit ID:
BERT Test Screen
Test Results
----------------------------------------------------
Test Direction: Customer
Unframed Pattern Generation: ON
Pattern: 2^23 Pattern
Line Coding: B8ZS
Bit Errors: 0000000
Bit Error Rate: 0.0E-05
Pattern Sync: ACQUIRED
Pattern Sync Losses: 000
Test Length (HH:MM:SS): 02:00:00
Time Elapsed (HH:MM:SS): 00:02:32
----------------------------------------------------
1. Number of Errors to Inject = 001 (Maximum=255)
2. Inject Bit Error
3. (Re)start
Selection: