Product specifications

12 Issue 1, November 2003 61181113L2-5A
The Provisioning Screen (Figure 13) displays current
provisioning settings for the HDSL2 circuit. Options
that can be changed from this screen are labeled with a
number (for example, “
1” for DSX-1 Line Build Out). To
change a particular option setting, select the appropriate
number and a new menu will appear with a list of the
available settings.
Note that there is more than one screen for the
Provi-
sioning Menu
. Press the N (and ENTER) to move forward
to the next screen. Figure 14 shows the remainder of the
Provisioning Menu. To return to the previous screen,
press
P. To return to the Main Menu, press <ESCAPE>.
To re-deploy this unit, pressing “
D” will restore the
factory default settings as shown in Table 4.
The options shown in Table 4 are available with the
1223026L2 H2TU-R. Some settings may differ when
using different H2TU-As.
Figure 13. Provisioning Screen, Page 1
Figure 14. Provisioning Screen, Page 2
Shelf: 1 Slot: 14 Total Access System 10/28/03 08:59
Unacknowledged Alarms: INFO
Circuit ID:
Provisioning
1. DSX-1 Line Buildout = 0-133 Feet
2. DSX-1/DS1 Line Code = B8ZS
3. DSX-1/DS1 Framing = ESF
4. Forced Frame Conversion = Disabled
5. Smartjack Loopback = Enabled
6. Loopback Timeout = 120 Min
7. Latching Loopback Mode = T1 (Disabled)
8. DS1 TX Level = 0 dB
9. Span Power = Enabled
10. Customer Loss Indicator = AIS / CI
11. PRM Setting = AUTO
12. Loop Atten Alarm Thres = 30dB
13. SNR Margin Alarm Thres = 04dB
14. Remote Provisioning = Enabled
15. Service State = OOS Maintenance
16. Network Source = DSX
N. Next Page
Selection:
Shelf: 1 Slot: 14 Total Access System 10/28/03 08:59
Unacknowledged Alarms: MAJOR INFO
Circuit ID:HntsvlALMn0103
Provisioning
17. External Alarms = Disabled
18. Auto In Service = Enabled
19. Auto IS Startup Period = 4 hours
20. Auto IS Off Period = 8 hours
D. Restore Factory Defaults
P. Previous Page
Selection: