Product specifications
22 Issue 3, December 2003 61223006L1-5C
Selecting option 2 from the Troubleshooting screen
accesses the
General Information Screen (Figure 30)
that summarizes the deployment guidelines necessary
to provision this HDSL2 circuit.
The
Virtual Terminal Session Screen (Figure 31) allows
control of the Remote card provisioning from the
H2TU-C. Press 1 from this screen to begin a user-
initiated session with the Remote card. When the
remote session is completed, Press
CTRL+X to terminate
the session.
Figure 30. General Information Screen
Figure 31. Virtual Terminal Control Screen
Circuit ID: 12/01/03 11:13:10
Press ESC to return to previous menu
HDSL2 Loop Guidelines for optimum operation
-------------------------------------------
Non-loaded cable pair
Single bridge tap < 2Kft
Total bridge taps < 2.5Kft
Bridge tap within 1000ft of transceiver may affect performance.
Impulse noise < 50dBrnF (F filter)
Wideband noise < 31dBrnF (f filter)
Power influence <= 80 dBrnC
Longitudinal Balance >= 60dB (If using Wideband test at 196 Khz >= 40dB)
Foreign DC Voltage (t-r,t-g,r-g) < 3VDC
Loop Resistance <= 775 ohms
Margin >= 6 dB
Attenuation <= 28 dB
Circuit ID: 12/01/03 11:15:11
Press ESC to return to previous menu
Virtual Terminal Session: Inactive
Virtual Host: no
Virtual Terminal Control
1. Log into H2TU-R
Selection: