Product specifications

16 Issue 3, December 2003 61223006L1-5C
This unit includes two terminal emulation modes. The
desired terminal mode can be selected from the
Terminal Modes Screen, illustrated in Figure 21.
Additionally, pressing
CTRL+T while on any screen can
toggle the two terminal modes.
The Manual Update Mode allows the user to manually
update the screens. This mode supports efficient print
screen and log file utilities for storage of key provi-
sioning parameters, alarm or performance history and
current system status. “3 SPACES TO UPDATE”
appears at the top of each screen. By pressing the
spacebar three times, the screen will be refreshed and
will reflect the most current circuit conditions and
provisioning options.
The second terminal emulation mode is the Real Time
Update Mode (VT100). This mode provides real time
updating of HDSL2 circuit conditions and provisioning
options as changes occur. The default mode is Real
Time Update.
Figure 21. Terminal Mode Screen
Circuit ID: 12/01/03 10:30:45
Press ESC to return to previous menu
TERMINAL MODES MENU
MANUAL UPDATE MODE:
* You can print or log screens
* No text is highlighted
* "3 SPACES TO UPDATE" appears at the top of each screen,
reminding you to press the spacebar 3 times to update the screen
* There is a delay between screen changes & updates
* After 30 min. of no interaction, a new baud rate search is begun
* Ignores input until screen is finished printing.
REAL-TIME UPDATE MODE:
* Faster of the two modes
* You cannot print screens to a log file
* Highlighting is enabled
* Recommended for daily operation