Chapter 6. Troubleshooting
6-2 Express 3010/3110 User Manual 61200239L1-20
Power/Line LED, 1, and 2 LEDs Flash Green
This indicates a configuration problem. Verify the following informa-
tion is correct:
•Switch Type
Service Profile Identifiers (SPIDs)
ISDN Phone Numbers
This information can be viewed by using the Express Configuration
program or the Configuration Screen in the VT 100 menu system. The
Link Status should indicate
Link Up
if all configuration information is
correct and the unit is properly connected. If the link status is good
and calls still cannot be placed, review the section
Dial-Up Connection
Problems
(below).
Auto-Detect can be enabled at the
Auto-Detect SPIDs/Switch
option
in the Configuration screen of the VT 100 menus to automatically de-
tect the SPIDs and the Switch Type.
Look for the following with the COM port setup:
IRQ conflicts
Wrong DTE speed
Power/Line LED, 1, and 2 LEDs flash green sequentially. After a
software upgrade, if the Power/Line, 1 and 2 LEDs flash green in
sequence, a problem occurred. Restart the download using the
instructions in Chapter 4. If the download fails a second time, contact
ADTRAN technical support.
Dial-Up Connection Problems
Many connection problems can be diagnosed by viewing the status
buffer message returned from the ISDN network and the Express.
These messages are accessed by choosing the
Status Buffer
button in
the
Diagnostics
tab of the ADTRAN Express Configuration window.