Specifications
BSAP limits.
Are the concurrent authenticated user and BSAP limits of the BSC hard limits or can they
be over-subscribed?
The concurrent authenticated user limits are hard limits. For example the BSC-600 supports 64
concurrent authenticated users. The 65th user will not be able to authenticate.
The BSAP limits are not currently hard limits but may be enforced in future releases. If you
over-subscribe the BSAP limit you will receive the following message in the web based
administrative gui.
"Supported Bluesocket Access Point Limit exceeded. Bluesocket recommends upgrading the
hardware, as clients may experience degradation. This limit will be enforced in all future
releases."
Can I disable https on the login page of the BSC or vWLAN and use http instead so I do
not get a certificate error?
No, https (http over ssl) is required to encrypt login transactions and cannot be disabled. It is
recommended you purchase and install a certificate from a trusted certificate authority such as
Verisign or Godaddy.
BSC-600/1200 web server will not start after changing timezone
I changed the timezone on my BSC-600/1200 and after a reboot the web server will not start.
How can I recover the BSC-600/1200.
1. Start with the BSC powered off. Connect a laptop with a nine-pin null-modem serial cable to
the BSC's serial console port. Use a terminal emulation program such as Microsoft
HyperTerminal (9600,8,none,1,none).
2. Power on the BSC. Immediately begin to press control-c repeatedly until the interrupt in the
boot process stops at a CFE> prompt. There is only a 2-3 second time frame for the interrupt
from the time BSC is powered on.
3. Set the date and time at the CFE prompt - commands are "set date" and "set time".
set date dy/mm/dd/yyyy