Specifications

Users that are inactive or have gone out of wireless range for some period of time are getting dropped
from active connections of the BSC and have to re-authenticate. An example would be a device that has
gone into sleep mode or an employee who has taken their laptop with them outside of the wireless
coverage area for a lunch meeting.
You can adjust the "Time in seconds before idle connections are timed out" under
general>misc>connection tracking. The default is 600 seconds (10 minutes). This means if a client is
inactive or goes away for 10 minutes they will be dropped from the BSC's active connection table and
have to re-authenticate. You could adjust this to 4 hours for example, 1/2 of a business day. This must be
set to greater than or equal to your DHCP lease. If you are using the BSC's DHCP server you can find the
DHCP lease under network>managed>click to edit the appropriate managed network interface>DHCP
server tab. If you are using DHCP relay make sure the setting is greater than or equal to your DHCP lease
time in your external DHCP server. If the BSC does not see the DHCP renew at half the lease interval the
client will be dropped from the connections table.
What are the rack space, environmental, power consumption and thermal output (BTU)
specifications of the BSCs?
BSC-600/1200
Rack Space: 1U Width: 380 mm (15 in) Depth: 290 mm (11.5 in) Height: 44.5 mm (1.75 in)
Operating Temp: 10 to 35 degrees C (50 to 95 degrees F)
Humidity: 40 to 80%, non-condensing
Power Consumption: 110-240V, 220 Watts
Thermal Output (BTU): 750 BTU/h
*Optional BSC-600/1200 PoE Power Supply (BSC-POE-000-00-00): 100-240V, 80 Watts, 275 BTU/h
BSC-2200/3200/5200
Rack Space: 2U Width: 445 mm (17.5 in) Depth: 450mm (17.7 in) Height: 89 mm (3.5 in)
Operating Temperature: 10 to 35 degrees C (50 to 95 degrees F)
Humidity: 40 to 80%, non-condensing
Power Consumption: 110-240V, 350 Watts
Thermal Output (BTU): 1200 BTU/hr
What is the default administrator user name/password of the web based administration console of
the BSC?
admin/blue
What is the default serial console password of the BSC?
wg1000s