Installation guide

BlueSecureAccess Point 1800 Installation Guide
6
Table 1: Status and Radio LED Definitions
Status 2.4Ghz LED 5Ghz LED Description
Yellow Solid Off Off Initial power-up
Green Solid Off Off Initializing software and acquiring an IP
address
Green Blink Off Off Discovering Bluesocket controller
Green Solid Green
Solid/Blink
Green
Solid/Blink
Radios Activated and passing traffic
Orange Solid Off Off Software Upgrade
Table 2: Network LED Definitions
Network LED Description
Off No Link Detected
Amber - ON 10/100 Link Detect with No Activity
Amber - Blinking 10/100 Link Detect with with Activity
Green - ON 1000 Link Detect with No Activity
Green - Blinking 1000 Link Detect with with Activity
The BSAP does not have a power switch. It’s powered on when connected to a Power over
Ethernet (PoE) from a PoE injector (BSAP-POE-001-00-0), switch or other network device that
supplies power over the network cable based on the IEEE 802.3af standard.
Ethernet/PoE Connector
The BSAP-1800 has one auto-sensing 10BASE-T/100BASE-TX/1000BaseT RJ-45 connector that
can be attached directly to 10BASE-T/100BASE-TX/1000BaseT switches to provide a full-duplex
link. These segments must conform to the IEEE 802.3 or 802.3u specifications.
This connector uses an MDI (i.e., internal straight-through) pin configuration. You can use
straight-through twisted-pair cable to connect this port to most network interconnection devices