Installation guide
Option Modules NetVanta 6355 PoE Hardware Installation Guide
28 Copyright © 2011 ADTRAN, Inc. 61200740E1-34D
Voice Interface Modules
NetVanta T1/PRI VIM (P/N 1200695L1)
The NetVanta T1/PRI VIM (see Figure 9) adds T1 voice capability to the NetVanta. See Table 6-5 on page 43
for the T1 connector pinouts. An optional DIM is required for dial backup applications. Dial backup is not
supported at this time.
Figure 9. NetVanta T1/PRI VIM
Features and Specifications
Operating Modes
• Primary Rate ISDN (PRI), CAS
T1 Interface
• Supported Standards: AT&T TR 62411,
AT&T TR 54016, Bellcore TR 194,
ANSI T1.403
• Line Rate: 1.544 Mbps +
75 bps
•Line Code: AMI or B8ZS
• Framing: D4 (SF) or ESF
• FT1 Line Rate: DS0 channelized
(multiples of 64 kbps)
• Input Signal: 0 to -36 dB (DS1)
• Line Build-Out: 0, -7.5, -15, -22.5 dB
(long), 0 to 655 ft (short)
• DS0 Assignment: Programmable
• Connector: RJ-48C
Clock Source
•Line
•Internal
•System
Diagnostics
• Test Pattern Generation and Detection:
QRSS, 2
15
- 1, all ones, all zeros
• Network loopbacks (local and remote);
responds to both inband and FDL loop
codes
• Alarm generation detection
• Network performance data (15 minutes
and 24 hours)
Compliance
• EMC - see Electromagnetic Compatibility
(EMC) Table on page 6.
• ACTA/FCC Part 68
• IC CS-03
• UL/CUL 60950
Environmental
• Operating Temperature: 0°C to 50°C
• Storage Temperature: -20°C to 70°C
• Relative Humidity: Up to 95 percent,
noncondensing
Physical
• Dimensions: 2.75-inch W x 4.25-inch D