NetVanta 6240/6250 Series IP Business Gateways Hardware Installation Guide 61700202G1-34B August 2013
Trademarks NetVanta 6240/6250 Series HIG Trademarks Any brand names and product names included in this manual are trademarks, registered trademarks, or trade names of their respective holders. To the Holder of the Manual The contents of this manual are current as of the date of publication. ADTRAN reserves the right to change the contents without prior notice.
NetVanta 6240/6250 Series HIG Conventions Conventions Notes provide additional useful information. Cautions signify information that could prevent service interruption or damage to the equipment. Warnings provide information that could prevent injury or endangerment to human life. 61700202G1-34B Copyright © 2013 ADTRAN, Inc.
Safety Instructions NetVanta 6240/6250 Series HIG Safety Instructions When using your telephone equipment, please follow these basic safety precautions to reduce the risk of fire, electrical shock, or personal injury: 1. Do not use this product near water, such as a bathtub, wash bowl, kitchen sink, laundry tub, in a wet basement, or near a swimming pool. 2. Avoid using a telephone (other than a cordless type) during an electrical storm. There is a remote risk of shock from lightning. 3.
NetVanta 6240/6250 Series HIG FCC-Required Information FCC-Required Information FCC regulations require that the following information be provided in this manual: 1. This equipment complies with Part 68 of Federal Communications Commission (FCC) rules and requirements adopted by America’s Carriers Telecommunications Association (ACTA). Each registered interface has a label that contains, among other information, a product identifier in the format US:AAAEQ##TXXXX.
FCC Radio Frequency Interference Statement NetVanta 6240/6250 Series HIG FCC Radio Frequency Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
Table of Contents Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Physical Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NetVanta 6240 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Shipping Contents . . . . . . . . . . . . . . .
Table of Contents 8 NetVanta 6240/6250 Series HIG Copyright © 2013 ADTRAN, Inc.
List of Figures Figure 1. Figure 2. Figure 3. Figure 4. Figure 5. Figure 6. Figure 7. NetVanta 6240 Front Panel Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NetVanta 6240 Rear Panel Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NetVanta 6250 Front Panel Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NetVanta 6250 Rear Panel Layout . . . . . . . . . . . . . . .
List of Figures 10 NetVanta 6240/6250 Series HIG Copyright © 2013 ADTRAN, Inc.
List of Tables Table 1. Table 2. Table 3. Table A-1. Table A-2. Table A-3. Table A-4. Table A-5. Table A-6. Table A-7. NetVanta 6240 Front Panel LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 NetVanta 6250 Front Panel LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 BBU Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
List of Tables 12 NetVanta 624050 Series HIG Copyright © 2013 ADTRAN, Inc.
1. INTRODUCTION This hardware installation guide describes the NetVanta 6240/6250 Series units’ physical characteristics, lists their features and specifications, introduces basic functionality, and provides installation instructions.
Physical Description 2. NetVanta 6240/6250 Series HIG PHYSICAL DESCRIPTION NetVanta 6240 Series The NetVanta 6240 Series is a multiservice Internet Protocol (IP) business gateway designed for use in integrated voice and data service offerings to small-to-medium sized businesses worldwide. This product line is a high-bandwidth business gateway designed to allow carriers to deliver up to 60 channels of Voice over IP (VoIP) to their customers.
NetVanta 6240/6250 Series HIG Physical Description Front Panel Features Status LEDs The status LEDs are located on the right side of the front panel. The STATUS LED indicates the unit’s status. The VOICE LED indicates the status of the voice ports. The NET 1 through NET 4 LEDs reflect the status of the network interfaces. The LAN 1 and LAN 2 LEDs reflect the status of the local area networks (LANs). Table 1 below describes the front panel LEDs. Table 1.
Physical Description NetVanta 6240/6250 Series HIG Rear Panel Interfaces VOICE Connection A single 50-pin female amphenol connector, labeled VOICE, provides the interconnect wiring for the analog FXS/FXO circuits. See Table A-1 on page 33 for voice connector pinouts. The status LED, labeled VOICE, is located on the front panel. The number of circuits used (1 through 24) is dependent on the model NetVanta 6240. FXO interfaces use circuits 17 through 24 depending on the model.
NetVanta 6240/6250 Series HIG Physical Description NetVanta 6250 Series The NetVanta 6250 Series is a multiservice Internet Protocol (IP) business gateway designed for use in integrated voice and data service offerings to small-to-medium sized businesses worldwide. This product line is a high-bandwidth business gateway designed to allow carriers to deliver up to 72 channels of Voice over IP (VoIP) to their customers.
Physical Description NetVanta 6240/6250 Series HIG Front Panel Features Status LEDs The status LEDs are located on the left side of the front panel. The VOICE LED indicates the status of the voice ports. The STATUS LED indicates the unit’s status. The GIG 1 LED indicates the status of the Gigabit Ethernet port (both fiber and copper). The USB LED indicates the status of the USB port. The T1 1 through 4 LEDs reflect the status of the network interfaces.
NetVanta 6240/6250 Series HIG Physical Description Rear Panel Design The NetVanta 6250 Series rear panel is shown below. T1 0/1 T1 0/3 ETH 0/1 ETH 0/3 FXO 0/0 VOICE AC INPUT GIG 0/1 T1 0/2 T1 0/4 ETH 0/2 ETH 0/4 USB 10/100/1000 BASE-T CRAFT RTN -48V DC IN BBU Figure 4. NetVanta 6250 Rear Panel Layout Rear Panel Interfaces VOICE Connection A single 50-pin female amphenol connector, labeled VOICE, provides the interconnect wiring for the analog FXS/FXO circuits.
Physical Description NetVanta 6240/6250 Series HIG DC Power Connection A DC input connector, labeled DC IN, is provided to power the unit from a -48 VDC power source. Refer to Supplying DC Power to the NetVanta 6250 on page 27 for connection details. Grounding Point A grounding point is provided to connect the unit to a protective earth ground. Refer to Supplying DC Power to the NetVanta 6250 on page 27 for connection details.
NetVanta 6240/6250 Series HIG 3.
Product Specifications NetVanta 6240/6250 Series HIG The NetVanta 6250 Series products have the following features: • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • 22 8, 16, or 24 FXS ports 16 FXS ports and 9 FXO ports 1 built-in FXO lifeline on the rear panel (F2 models only) 4 T1 WAN (RJ-48C) interfaces 1 routed 10/100/1000Base-T Ethernet port (copper RJ-45 and fiber SFP) 4 routed auto MDI/MDIX 10/100Base-T Ethernet ports (RJ-48C) EIA-232 craft port (DCE) provided for local man
NetVanta 6240/6250 Series HIG 4. Unit Installation UNIT INSTALLATION The instructions and guidelines provided in this section cover hardware installation topics, such as mounting options and supplying power to the unit.
Unit Installation NetVanta 6240/6250 Series HIG Mounting Options The unit may be installed in rackmount, wallmount, or tabletop configurations. The following sections provide step-by-step instructions for rack mounting and wall mounting. Rack Mounting the NetVanta The NetVanta is a 1U-high, rack-mountable unit that can be installed into 19-inch or 23-inch equipment racks. The following steps guide you in mounting the NetVanta into a rack. ADTRAN recommends 1U (1.
NetVanta 6240/6250 Series HIG Unit Installation Wall Mounting the NetVanta By following these instructions exactly, the NetVanta can be safely mounted on the wall. • • • To avoid damaging the unit, use only the screws included in the shipment when attaching mounting ears to the chassis. When wall mounting the NetVanta, care must be taken not to damage the power cord. Do not attach the power cord to the building surface or run it through walls, ceilings. floors, or openings in the building structure.
Unit Installation NetVanta 6240/6250 Series HIG Figure 5. Wallmount Installation 26 Copyright © 2013 ADTRAN, Inc.
NetVanta 6240/6250 Series HIG Unit Installation Supplying Power to the Unit The NetVanta 6240/6250 Series units come equipped with a 120 VAC, 60 Hz power supply for connecting to a properly grounded power receptacle. (A detachable power cable with a grounded, three-prong plug comes with the shipment.) To power this unit, connect the power cable to an appropriate AC power source.
Unit Installation NetVanta 6240/6250 Series HIG Instructions for Connecting DC Power Source to the NetVanta 6250 Step Action 1 Insert the positive terminal of the DC power source into left position of the two-position terminal block (labeled RTN on the NetVanta 6250). Tighten the screw. 2 Insert the negative terminal of the DC power source into the right position of the two-position terminal block (labeled -48V on the NetVanta 6250). Tighten the screw.
NetVanta 6240/6250 Series HIG Unit Installation Optional Battery Backup Unit (P/N 1175044L1/L2) The ADTRAN battery backup unit (BBU) is an optional device designed as a backup DC power supply for the NetVanta 6240/6250 Series. The BBU connects to the NetVanta 6240/6250 through a 6-foot charge/discharge, 2-conductor wire with a keyed modular plug (included with the BBU). The 1175044L1 BBU is a low profile wallmount configuration.
Unit Installation NetVanta 6240/6250 Series HIG Wall Mounting the BBU Figure 7 shows the BBU (P/N 1175044L1) mounting dimensions for the NetVanta 6240/6250 Series. Figure 7. Wall Mounting the BBU Install the BBU as follows: Instructions for Wall Mounting the BBU Step Action 1 Decide on a location for the BBU, keeping in mind that the cable plugs must be able to reach their designated sockets in the NetVanta unit.
NetVanta 6240/6250 Series HIG Unit Installation BBU Maintenance • • • • The BBU does not require routine maintenance for normal operation. The life expectancy of the BBU is 3 to 5 years on standby when used at room temperature. Excessive heat decreases battery power and life. Extreme low temperature also decreases battery capacity. Ideal ambient temperature for battery life and capacity is 20°C. Battery shelf life is extended in cooler temperatures.
Unit Installation 32 NetVanta 6240/6250 Series HIG Copyright © 2013 ADTRAN, Inc.
APPENDIX A. CONNECTOR PIN DEFINITIONS The following tables provide the pin assignments for the base unit. Table A-1.
Appendix A NetVanta 6240/6250 Series HIG Table A-2.
NetVanta 6240/6250 Series HIG Appendix A Table A-3. FXO Connector Pinouts Pin Name Description 1, 2 — 3 Ring 4 Tip Tip lead of the 2-wire interface 5, 6 — Unused Unused Ring lead of the 2-wire interface Table A-4. T1 Port Pinouts Pin Name Description 1 RX Receive data from the network–Ring 2 RX Receive data from the network–Tip 3 — Unused 4 TX Transmit data toward the network–Ring 5 TX Transmit data toward the network–Tip 6-8 — Unused Table A-5.
Appendix A NetVanta 6240/6250 Series HIG Table A-7. CRAFT Port Pinouts 36 Pin Name Description 1 DCD Data Carrier Detect (output) 2 TXD Receive Data (output) 3 RXD Transmit Data (input) 4 DTR Data Terminal Ready (input) 5 GND Signal Ground 6 DSR Data Set Ready (output) 7 RTS Request to Send (input) 8 CTS Clear to Send (output) 9 — Unused Copyright © 2013 ADTRAN, Inc.