Specifications

Section 4.1 Commons User Interface Guide Total Access 600 Series System Manual
52 © 2002 ADTRAN, Inc. 61200624L1-1A
Session Management Keystrokes
Configuration Keystrokes
To do this... Press this
key...
Log out of a session (Telnet Connection) CTRL+L
Refresh the screen
To save time, only the portion of the screen that has changed is refreshed. This option
should only be necessary if the display picks up incorrect characters.
CTRL+R
To do this... Press this
key...
Restore factory default settings.
This setting restores the factory defaults based on the location of the cursor.
F
Copy selected items to the clipboard.
The amount of information you can copy depends on the cursor location when you
press <C>:
If the cursor is over an editable field, only that item is copied.
If the cursor is over the index number of a list, then all of the items in the row of the list
are copied. For example, if the cursor is over the DS0 field in the E
DIT/VIEW MAP
screen, all of the information associated with the DS0 is copied.
C
Paste the item stored in the clipboard, if the information is compatible.
You must confirm all pastes - except those to a single editable field.
P
Increment the value of certain types of fields by one when you paste information into
those fields.
>
Decrement the value of certain types of fields by one when you paste information into
those fields.
<
Insert a new list item.
For example, add a new item to the T
ELNET USER LIST connection list by pressing <I>
while the cursor is over the index number.
I
Delete a list item.
For example, delete an item from the T
ELNET USER LIST connection list by pressing <D>
while the index number is active.
D