Specifications

408 © 2002 ADTRAN, Inc. 61200624L1-1A
Section 5 DLP-015 Total Access 600 Series System Manual
Purchase of a T1 TDM 612/616/624 Unit with the EC/ADPCM Card Installed for Later
Upgrade to ATM
For customers who plan to operate a TDM application initially, but eventually upgrade to an ATM
application, a Total Access 612/616/624 unit may be purchased with the EC/ADPCM card installed
(P/N 4200612L2#TDM, 4200616L2#TDM, 4200642L2#TDM).
1. When the circuit is converted to ATM, the customer may obtain the latest VoATM firmware from the
ADTRAN website (http://www.ADTRAN.com). Select S
UPPORT>POST-SALES TECHNICAL
S
UPPORT>FIRMWARE UPDATES>612/616/624 ATM or contact Post-Sales Technical Support at 888-
4ADTRAN.
2. Upgrade the Total Access 612/616/624 with the latest VoATM firmware. Instructions for upgrading the
unit can be found in DLP-007 and DLP-008.
3. Factory default the Total Access 612/616/624 by one of the following methods:
•Select S
YSTEM UTILITY>TERMINAL MODE. At the > prompt, type fac. You will then see “Restore
Factory Defaults and Reset Unit? (press 'y').” Press the y key to confirm default. The unit then
resets.
If connected to the CRAFT port, power reset the unit and then restore power to the unit while
holding down the F key. You will then be prompted to confirm the factory default.
4. In the ATM code, the upgrade was successful if the following two things occur:
•The S
YSTEM INFO>FIRMWARE REVISION field does not display Error.
When you select the M
ODULES>MODULES menu, the EC/ADPCM appears in Slot 7 as shown in
the following screen.
5. Reconfigure the unit for the specific application.
Follow-up Procedures
Once this procedure is complete, return to the procedure which referred you to this DLP and continue with
the tasks indicated there.