Specifications
61200624L1-1A © 2002 ADTRAN, Inc. 407
Total Access 600 Series System Manual Section 5 DLP-015
8. Upgrade the Total Access 612/616/624 with the latest VoATM firmware. Instructions for upgrading the
unit can be found in DLP-007 and DLP-008.
9. Factory default the Total Access 612/616/624 by one of the following methods:
•Select S
YSTEM UTILITY>TERMINAL MODE. At the > prompt, type fac. You will then see “Restore
Factory Defaults and Reset Unit? (press 'y').” Press the y key to confirm default. The unit then
resets.
• If connected to the CRAFT port, power reset the unit and then restore power to the unit while
holding down the F key. You will then be prompted to confirm the factory default.
10. In the ATM code, the upgrade was successful if the following two things occur:
•The S
YSTEM INFO>FIRMWARE REVISION field does not display Error.
• When you select the M
ODULES>MODULES menu, the EC/ADPCM appears in Slot 7 as shown in
the following screen.
11. Reconfigure the unit for the specific application.