Specifications

406 © 2002 ADTRAN, Inc. 61200624L1-1A
Section 5 DLP-015 Total Access 600 Series System Manual
DLP-015
Purchase of Upgrade Package from ADTRAN
The upgrade package may be purchased from ADTRAN. This package includes the EC/ADPCM
(P/N 1200613L1) and the ADTRAN installation and test. If this package is ordered, the customer must
send the Total Access TDM 612/616/624 unit back to ADTRAN. Once received, the EC/ADPCM module
is installed along with the latest VoATM firmware. The upgraded unit is then tested and returned to the
customer. Please call ADTRAN CAPs department at 800-9-ADTRAN extension 7722 for this service.
Purchase and Installation of the EC/ADPCM Module by the Customer
An EC/ADPCM module may be purchased separately and installed in the Total Access 612/616/624 T1
TDM unit by the customer.
1. Remove power from the Total Access 612/616/624.
2. Remove the screws from the back of the Total Access 612/616/624, and then remove the cover.
3. Install the EC/ADPCM Module in the Total Access 612/616/624 as shown in the following figure.
*
4. Remove the two screws from the motherboard, install the two standoffs, and insert the screws through
the top the EC/ADPCM board into the standoffs.
5. Replace the cover on the Total Access 612/616/624 and tighten the screws.
6. Restore power to the Total Access 612/616/624.
7. Obtain the latest VoATM firmware from the ADTRAN website (http://www.ADTRAN.com). Select
S
UPPORT>POST-SALES TECHNICAL SUPPORT>FIRMWARE UPDATES>612/616/624 ATM or contact Post-
Sales Technical Support at 888-4ADTRAN.
Perform Steps Below in the Order Listed
Network Card
FXS Card
EC/ADPCM Card
(Installed and secured)