Specifications
Section 2 Engineering Guidelines Total Access 600 Series System Manual
38 © 2002 ADTRAN, Inc. 61200624L1-1A
Analog Ports
Number of FXS Ports 4 ports for Total Access 604
8 ports for Total Access 608
12 ports for Total Access 612
16 ports for Total Access 616
24 ports for Total Access 624
Modes FXS Loop Start
FXS Ground Start
TR08 Single
TR08 UVG
DP0
Tandem (E&M)
Ringing Unbalanced ringing, 5 REN per port not to
exceed 35 REN (Total Access 612/616/624)
Balanced ringing, 3.75 REN per port not to
exceed 15 REN (Total Access 604/608)
Ring Voltage Fixed 88 Vrms ringer (Total Access
612/616/624)
Programmable ring voltage from 45 Vrms-62
Vrms (Total Access 604/608)
Routing (Ethernet)
Specifications IEEE 802.3
IP Support TCP, RIP V1, RIP V2, UDP, ICMP, ARP, UDP
Relay, SYSLOG
PPP Support LCP, IPCP, BCP
DHCP DHCP Server to LAN
DHCP from network (NAT)
Management
Craft Interface EIA 232, Physical RJ-48C
Ethernet 10/100BaseT
Interface
SNMP V1 support
• 604/608 ATM units running D.01.36
firmware or previous
• 612/616/624 ATM units running D.01.30
firmware or previous
SNMP V2 support
• TDM units running A.04 firmware or later
Full menu-driven Telnet access
Software download via TFTP
Support for VoDSL gateway management
systems and firmware download
Table 14. Specifications (Continued)
Application Feature Specification