Specifications

Section 2 Engineering Guidelines Total Access 600 Series System Manual
36 © 2002 ADTRAN, Inc. 61200624L1-1A
Battery Backup Connection
An optional battery backup system is available for the Total Access 604/608 (P/N 1200641L1) and the
Total Access 612/616/624 (P/N 1175044L1, 1175044L2, or 1175044L4). Refer to the documentation
available for your specific battery backup unit.
AC Power Connection
Each unit includes an auto ranging 90-250 VAC, 50/60 Hz power supply with a 3-prong removable cable.
Connect the power supply to a standard 120 VAC, 60 Hz electrical outlet for proper operation.
5. DB-9 TO RJ ADAPTER
The DB-9 to RJ adapter is used to connect a PC or VT100 terminal to the CRAFT port. This adapter does
not ship with the unit. A customer can obtain a free adapter (P/N 3196ADPT001) by contacting ADTRAN
Technical Support or can order the adapter with the unit. Customers can also build their own adapters by
purchasing unassembled adapter kits through companies like Black Box and Datacomm Warehouse. The
adapter pinout is shown in Table 13.
P 103 Transmitted data (TD-A) from DTE
S 103 Transmitted data (TD-B) from DTE
Y 114 TX clock (TC-A) to DTE
AA 114 TX clock (TC-B) to DTE
U 113 External TX clock (ETC-A) from DTE
W 113 External TX clock (ETC-B) from DTE
NN Test mode (TM) to DTE
Table 13. DB-9 to RJ Adapter Pinout
DB-9 RJ-45 DESCRIPTION
25 TX Data
3 3 RX Data
51 GND
Note: All other pins are unused.
Table 12. V.35 Interface Pinout (Continued)
PIN CCITT DESCRIPTION