Specifications
Section 4.6 SHDSL ATM UIG Total Access 600 Series System Manual
334 © 2002 ADTRAN, Inc. 61200624L1-1A
Managing the Modules – Modules
Use the MODULES menu to view and set the parameters shown in Figure 17. The Total Access 600
contains four fixed modules: The WAN/Network interface, FXS, Echo Canceller/ADPCM module, and the
V.35 interface. The M
ODULES table allows management of the on-board modules in the Total Access 600.
This menu contains M
ENU, ALARM, TEST, and STATUS indicators/menus customized for each module.
Figure 17. Modules Menu
>NET (SHDSL)
Menu
Data Rate
Used to select data rate of the network connection. (This should match the DSLAM settings.)
Frame Mode
Used to select either SDSL Framed (def) or SDSL Framed Plesiosynchronous with bit stuffing. (This
should match the DSLAM settings.)
Annex A/B
Used to select ANNEX A, ANNEX B, or both.
ITU-991.2/Gspan
Chooses between ITU-T 991.2 or GLOBESPAN V1.2.
Test
These tests are meant for debug purposes only. A reboot may be required to return the Total Access 600 to
normal operation.
Network Loopback
Sets the network interface in loopback mode.