Specifications

Total Access 600 Series System Manual Section 4.6 SHDSL ATM UIG
61200624L1-1A © 2002 ADTRAN, Inc. 331
Sys log Host
Set this to the IP address or domain name (if DNS configured) of the sys log host device. All log events are
sent to this device.
PPP Log
Information pertaining to the PPP negotiation and authentication is logged in the PPP log.
Connection Log
Information pertaining to the call placement and answering is logged in the Connection log.
Network Log
Information pertaining to routing protocols is placed in this log.
Each log (PPP log, Connection log, and Network log) contains the following elements.
Active
When set to YES (def), PPP events below or equal the log level are logged into the log.
Wrap
When set to YES (def), new PPP events will overwrite old PPP events when the log is full. All logging
will stop when the log is full and set to
NO.
Level
In order to log events, they must be at or below this level. Range is 0 to 6. The default is 3.
View
This menu displays the log list. The fields are as follows:
Clear
This clears the log when activated.
DATE/TIME
Date and time event occurred.
LEVEL
Level associated with this event (0-6).
MESSAGE
Text message for this event. If message is too
long to fit on the line, another event appears
below it continuing the message.