Voice Turn Up
Step Action
1.
From the Total Access 600 main menu, select the WAN menu. Select
DSLAM TYPE and select the name of the DSLAM type you are using.
(At this point you need to back out of the menu to save the changes.
The unit will need to reboot if it was not previously configured for this
DSLAM type.)
2.
Select DSL RATE CONFIG (BIT RATE) and change the setting to match
that in your DSLAM. (If this field is read-only, allow a few seconds for
autobaud to expire and the field will change to writeable.)
3.
Select WAN, and then select the ATM CONFIG menu.
4.
Enter the IDLE CELLS format for your network.
5.
Set DATA SCRAMBLING appropriately for your network.
6.
Back all the way out to the top level Total Access 600 menu, and then
select the V
OICE menu. (From this menu, the appropriate Voice
information for working with the Voice Gateway is entered.)
7.
Select CONFIG, and from the CONFIG menu, enter the Gateway type
under C
ALL CONTROL and enter the VPI and VCI values for
communicating with that Gateway.
CALL CONTROL should be set to the Gateway type, and the VPI and VCI
values should be set appropriately for your network.
8.
To verify correct setup, use the STATUS menu (under the VOICE menu)
to look at the current status of the voice connection.
Under STATUS, you can view the GATEWAY STATS and information
about the voice PVC along with information about the POTs ports
available on the Gateway.
The G
ATEWAY STATS menu should show the Gateway Link is up (if
everything is configured correctly).
A visual inspection of the VOICE LED on the front panel will also yield
the status. Green = Up. Red = Down.