Managing the Modules – Modules
Use the MODULES menu to view and set the parameters shown in Figure 17. The Total Access 600
contains four fixed modules: The WAN/Network interface, FXS, Echo Canceller/ADPCM module, and the
V.35 interface. The M
ODULES table allows management of the on-board modules in the Total Access 600.
The table contains M
ENU, ALARM, TEST, and STATUS indicators/menus customized for each module.
Figure 17. Modules Menu
>NET (SDSL)
Test
These tests are meant for debug purposes only. A reboot may be required to return the Total Access 600 to
normal operation.
Network Loopback
Sets the network interface in loopback mode.
Send/Check 2047
Sends and checks a 2047 BERT pattern over the network interface (assuming LTU in loopback). Results
of the test can be found in Test Results.
Send/Check ALT
Sends and checks an alternating pattern over the network interface (assuming LTU in loopback). Results
of the test can be found in Test Results.
>FXS
Refer to Section 7, FXS User Interface Guide.
>EC/ADPCM
Refer to Section 7, FXS User Interface Guide.