Specifications
Total Access 600 Series System Manual Section 4.3 T1 ATM UIG
61200624L1-1A © 2002 ADTRAN, Inc. 185
Managing the Modules – Modules
Use the MODULES menu to view and set the parameters shown in Figure 17. The Total Access 600
contains four fixed modules: The WAN/Network interface, FXS, Echo Canceller/ADPCM module, and the
V.35 interface. The M
ODULES table allows management of the on-board modules in the Total Access 600.
The table contains M
ENU, ALARM, TEST, and STATUS indicators/menus customized for each module.
Figure 17. Modules Menu
>NET (T1)
Menu
Format
Sets the frame format for the T1 interface. The setting must match the frame format of the circuit to
which the interface is connected. Choices are ESF (extended superframe), SF (superframe), or SLC96.
Line Code
Sets the line code for the T1 interface. The setting must match the line code of the circuit to which the
interface is connected. Choices are B8ZS (bipolar with 8-zero substitution) or AMI (alternate mark
inversion).
Equalization
Sets the line build-out for the T1 interface. The setting of this field depends on whether the circuit is
provisioned for DS1 by the telephone company. Choices are
0dB,-7.5dB,-15dB,-22dB,266FT,399FT,533FT,and 655 FT.
SF is equivalent to the D4 frame format.