Datasheet

jobAid
DESCRIPTION
TheSmallFormFactorPluggable10GigabitEthernetXFP,1550
nm,CommercialTemperature(XFP)opticaltransceiverisafully
duplexserialelectric,serialopticdevicewithbothtransmitand
receivefunctionscontainedinasinglemodulethatprovidesa
highspeedseriallinkat10Gb/s.Installedintoanappropriate
host
module,theXFPprovidesa10Gigabitinterfacetothe
supportingsystem.
ThetransmitsideoftheXFPconvertsserialNRZelectricaldateat
the10Gb/slineratetoastandardcompliantopticalsignal.The
receivesideoftheXFPconvertstheincomingDCbalancedserial
NRZopticaldataatthe
10Gb/slinerateintoserialelectricaldata.
NOTE
Toensurecompatibility,refertothedoc umentationpr ovided
withthehostmodule.
ThefollowingfeaturesaresupportedontheXFP:
1550nmopticalsignalsforupto80kmreach
Lowpowerconsumption(<3.5Wmax)
ExcellentEMIperformance
Biterrorrate10^12
CAUTION
!
Duetocompliancecertificationrequirements,onlyXFPssupplied
byADTRANaretobeusedwiththehostmodule.ADTRAN
cannotcertifysystemintegritywithotherXFPs.
Operational Specifications
OpticalSpecifications:
TransmitWavelength:1550nm
ReceiveWavelength:1530to1565nm
Datarate:9.95Gb/sto11.1Gb/s
Opticaltransmitlevel:0to+4.0dBm
Small Form-Factor Pluggable
10 Gigabit Ethernet XFP, 1550 nm
Commercial Temperature
Opticalreceivelevel:greaterthan–24dBm
Opticaldistance:80kmmaximum
Opticalconnectors:LC
ExtendedEnvironmentalSupport:
Operationaltemperaturerange:0°Cto+70°C
Storagetemperaturerange:–40°Cto+85°C
Relativehumidityto85%,noncondensing
INSTALLATION
InspecttheXFP.Ifdamaged,fileaclaimwiththecarrierandthen
contactADTRANCustomerService.
ToinstalltheXFPintoanappropriatemodule,completethe
followingsteps:
1. InserttheXFPintotheXFPcageonthecircuitboardofthe
hostmodulewiththelatchhandlefacingoutward.Slidethe
XFPallthewayintothereceptacle.
NOTE
ThelatchontheXFPisforremovalonly.WhenremovingtheXFP,
rotatethelatchawayfromtheXFPcageuntilaphysicalclick
occurs.TheXFPshouldslideeasilyoutofthecage.
2. Usingthumbandforefinger,exertadequatepressureto
ensuretheXFPiscompletelyseatedintheXFPcage.
3. Donotremovetheconnectorpluguntiltheopticalfiber
connectionismade.
NOTICE
Itisrecommendedthattheconnectorplugremainonwhenever
thetransceiveropticalfiberconnectorisnotinserted.
4. Continuetheinstallationandturnupofthehostmodule
usingtheinstructionsintheJobAidprovidedwiththat
module,orusingtheInstallationandMaintenancePractice
(I&M),availableonlineatwww.adtran.com.
PROVISIONING
TheXFPisnotdirectlyprovisionable.ToprovisiontheXFP,
accessthemenusystemofthehostmodule.Refertothe“Provi
sioning”sectionoftheJobAidorInstallationandMaintenance
Practiceprovidedwiththehostmoduleforprovisioningdetails.
CLEI: BVL3AGKD_ _
Product P/N: 1442980G1C
Issue Date: 0909
Document P/N: 61442980G1C-22A

Summary of content (2 pages)