Datasheet
jobAid
DESCRIPTION
The10GigabitEthernetXFP,1550nm,Commercial
Temperature(XFP)opticaltransceiverisafullduplexserial
electric,serialopticaldevicewithbothtransmitandreceive
functionscontainedinasinglemodule.The XFPprovidesa
highspeedseriallinkat10Gb/s.Installedintoanappro‐
priatehostmodule,the
XFPprovidesa10Gigabitinterface
tothesupportingsystem.
ThetransmitsideoftheXFPconvertsserialNRZelectrical
dateatthe10Gb/slineratetoastandardcompliantoptical
signal.ThereceivesideoftheXFPconvertstheincoming
DCbalancedserialNRZopticaldataatthe10Gb/s
linerate
intoserialelectricaldata.
NOTE
To ensure compatibility, refer to the documentation
providedwiththehostmodule.
ThefollowingfeaturesaresupportedontheXFP:
♦ 1550nmopticalsignalsforupto40kmreach
♦ Casecommercialtemperaturerangefrom0°Cto70°C
♦ Lowpowerconsumption(<3Wmax)
♦ ExcellentEMIperformance
CAUTION
!
Dueto compliancecertif icatio nrequirements,only XFPs
suppliedbyADTRANaretobeusedwiththehostmodule.
ADTRANcannotcertifysystemintegritywithotherXFPs.
Small Form-Factor Pluggable
10 Gigabit Ethernet XFP, 1550 nm,
Commercial Temperature
Operational Specifications
♦ OpticalSpecifications:
◊ TransmitWavelength:1550nm
◊ ReceiveWavelength:1530to1565nm
◊ Datarate:9.95Gb/sto11.3Gb/s
◊ Opticaltransmitlevel:–1to+2dBm
◊ Opticalreceivelevel:>–16dBm
◊ Opticaldistance:40kmmaximum
◊ Opticalconnectors:LC
♦ ExtendedEnvironmentalSupport:
◊ Operationaltemperaturerange:0°Cto+70°C
◊ Storagetemperaturerange:–40°Cto+85°C
◊ Relativehumidityto85%,noncondensing
INSTALLATION
InspecttheXFP.Ifdamaged,fileaclaimwiththecarrier
andthencontactADTRANCustomerService.
ToinstalltheXFPintoanappropriatemodule,complete
thefollowingsteps:
1. InserttheXFPintotheXFPcageonthecircuitboard
ofthehostmodulewiththelatchhandlefacingout‐
ward.Slide
theXFPallthewayintothereceptacle.
NOTE
ThelatchontheXFPisforremovalon ly.Whenremoving
theXFP,rotatethe latchawayfromtheXFPcageuntila
physicalclickoccurs.TheXFPshouldslideeasilyoutofthe
cage.
2. Usingthumbandforefinger,exertadequatepressure
toensuretheXFPiscomp letelyseatedintheXFP
cage.
3. Donotremovetheconnectorpluguntiltheoptical
fiberconnectionismade.
NOTICE
Itisrecommendedthattheconnectorplugremainon
wheneverthe transceiveropticalfiberconnectorisnot
inserted.
4. Continuetheinstallationandturn‐upofthehost
moduleusingtheinstructionsintheJobAidprovided
withthatmodule,orusingtheInstallationand
MaintenancePractice(I&M),availableonlineat
www.adtran.com
.
CLEI: BVL3AFKD_ _
Product P/N: 1442940G1C
Issue Date: November 2010
Document P/N: 61442940G1C-22A