Datasheet
C A U T I O N
C A U T I O N
!
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
Warranty: ADTRAN will replace or repair this product within the warranty period if it does not
meet its published specifications or fails while in service. Warranty information can
be found online at www.adtran.com/warranty
.
©2010 ADTRAN, Inc. All Rights Reserved.
ADTRAN CUSTOMER CARE:
From within the U.S. 1.800.726.8663
From outside the U.S. +1 256.963.8716
PRICING AND AVAILABILITY 1.800.827.0807
*61442701PG2-22C*
2. Thisdevicemustacceptanyinterferencereceived,including
interferencethatmaycauseundesiredoperation.
ChangesormodificationsnotexpresslyapprovedbyADTRAN
couldvoidtheuserʹsauthoritytooperatethisequipment.
CAUTION
C
TheSFPOC3containsaClass1laserthatcomplieswiththeLaser
SafetyrequirementsofFDA21CFR1 040.10and1040.11,andEN
60825‐1,and‐2.TheSFPOC3isNRTLListedandCBCertifiedto
allapplicableAmericanandEuropeansafetystandards.
CAUTION
!
♦ PerGR‐1089‐CORESection9,theSFPOC3 does not have an
internal DC connection between battery return and
frame ground.
♦ TheADTRANsystemthattheSFPOC3isbeingdeployedinis
designedandinte ndedforins tall ationaspartofaCommon
BondingNetwork(CBN),orIsolatedBondingnetwork(IBN).
♦ TheSFPOC3canbeinstalledinaDC‐I(isolated)orDC‐C
(common)configuration.Forinstallationswher eothercards
orthehostsystemhaveinternalconnectionsbetweenbattery
returnandframeground,thesystemwouldbe intendedfor
deploymentonlyinaDC‐Cconfiguration.
♦ TheADTRANsystemchassis framegroundterminalmustbe
connectedtoareliableearth ground toensurethatthemetal
enclosureof theSFP OC3is pr operlygrounded vi athe
backplaneconnector.
NOTE
♦ TheOC‐3port(s)areopticalandthereforearenotclassifiedas
anytypeofportasdefinedinAppendixBofGR‐108 9‐CORE
Issue5.
♦ ThisSFPOC3iscompliantwithSFF‐8472“DigitalDiagnostics
MonitoringInterfaceforOpticalTransceivers,”Revision9.3.
♦ This SFPOC3 iscompliant with theSmall Form‐Factor
Pluggable(SFP)Multi‐SourceAgreement(MSA).
♦ Thi sproductisdesigned to bedeployedinGR‐3108‐CORE
environmentclass1or2asdefinedinGR‐3108‐COREissue2.
TheSFPOC3isdesignedtomeetthefollowingenvironmental
classes:
♦ ETSIEN300019‐1‐1“Classificationofenvironmental
conditions;Storage,”Class1.2
♦ ETSIEN300019‐1‐2“Classificationofenvironmental
conditions;Transportation,”Class2.3
♦ ETSIEN300019‐1‐3“Classificationofenvironmental
conditions;Stationaryuseatweather‐protectedlocations,”
Class3.3
♦ ETSIEN300386“ElectromagneticcompatibilityandRadio
spectrumMatters(ERM);Telecommunicationnetwork
equipment;ElectromagneticCompatibility(EMC)
requirements”
Theequipmentisdesignedtofunctionwithoutdegradation
duringexposuretoalltestseveritiesperClass3.3.
ThisproductmeetsEURoHSDirective2002/95/ECand/orappli‐
cableexemptions.Refertowww.adtran.com
forfurtherinfor‐
mationonRoHS/WEEE.


