Installation guide

Unit Installation NetVanta 2000 Series Hardware Installation Guide
30 © 2004 ADTRAN, Inc. 61202361L2-34B
NetVanta 2300 and NetVanta 2400
The AC powered NetVanta 2300 and NetVanta 2400 come equipped with an auto-sensing 100-250 VAC,
50-60 Hz power supply for connecting to a grounded power receptacle. A grounded, three-plug, detachable
cable is included with the shipment for connecting to an appropriate power source.
This unit shall be installed in accordance with Articles 300 and 400 of the NEC NFPA
70.
Power to the Netvanta 2050/2054/2100 system must be from a grounded 120 VAC,
60 Hz source.
Maximum recommended ambient operating temperature is 45
o
C.
This unit shall be installed in accordance with Articles 300 and 400 of the NEC NFPA
70.
Power to the NetVanta 2300/2400 AC system must be from a grounded 100-250 VAC,
50/60 Hz source.
The power receptacle uses double-pole, neutral fusing.
Maximum recommended ambient operating temperature is 45
o
C.