User manual

Chapter 5 Config Menu TSU ACE User Manual
38 © 2003 ADTRAN, Inc. 61202295L1-1A
Figure 5-2. Network Submenu
Clock Sources and Timing
The TSU ACE operates from various clock sources, permitting it to perform properly in many different
applications. Use the
C
ONFIG
> N
ETWORK
(NI) > 5)C
LOCK
S
OURCE
: menu to set the network interface
clocking options (network, DTE, or internal timing). See the descriptions for Network Timing on page 39,
DTE Timing on page 39, and Internal Timing on page 40.
Table 5-1. Network Interface Submenus
Submenu Description
FORMAT Sets the frame format for the NI.
Choices: D4, ESF, AUTO
a
a D4 is equivalent to Superframe Format (SF).
CODE
Sets the line code for the NI.
Choices: AMI, B8ZS
YEL ALRM
Enables and disables the transmitting of yellow alarms.
Choices: ENA (enable), DISA (disable)
XMIT ALRM
Enables and disables the transmitting of performance report message (PRM) data on the
facility data link (FDL). The PRM data continues to be collected even if XMIT PRM is disabled
(possible only with ESF Format).
Choices: ON, OFF
CLOCK SOURCE
b
b For more information on clock sources and timing, see Clock Sources and Timing on page 38.
Selects the clock source for transmission toward the network from the NI.
Choices: NETWORK, DTE, INTERNAL
SET LBO
Selects the line build-out (amount of attenuation, in dB) for the network interface.
Choices: 0, 7.5, 15.0, 22.5
The clocking option selected always designates the clock source for transmission.
Clocking necessary for receiving data is always recovered from incoming data.