Chapter 5. Configuration Menu
5-16 TDU 120e User Manual 61202156L1-1
DBU config -- DBU operation
Under Nx56/64 config, the menu items are:
DSO Rate
This sets the base rate of the interface. The actual data rate
depends on the number of DS0s assigned to the Nx port.
Choices: 56K or 64K
TX CLK CNTRL
Controls the clock used by the TDU 120e to accept transmit
(TX) data from the DTE. The default is normal. If the interface
cable is long, causing a phase shift in the data, the clock can
be selected as I
NVERT
. This switches the phase of the clock
which should compensate for a long cable.
Choices: Normal, Invert
Data
Used to control the inverting of the DTE data. This inversion
can be useful when operating with an HDLC protocol. Often
used as a means to ensure 1s density.
Choices: Normal or Invert
CTS
Used to control characteristics of CTS.
Choices: Normal, (see Table 5-1) or Force On
DCD
Data Carrier Detect. Indicates to the DTE when a valid signal
is being received at the Network Interface.
Choices: Normal (see Table 5-1) or Force On
DSR
Data Set Ready. This signal indicates to the DTE when the
DCE is turned on and ready for operations.
Choices: Normal (see Table 5-1) or Force On
If
I
NVERT
is selected, zero (0) inhibit should also be selected to pre-
vent an open DTE input from placing zeros on the network.