A supplementary equipment grounding conductor shall
be installed between the product or system and ground
that is in addition to the equipment grounding conductor
in the power supply cord.
The supplementary equipment grounding conductor
shall not be smaller in size than the ungrounded branch-
circuit supply conductors.
The supplementary equipment grounding conductor
shall be connected to the product at the terminal
provided.
It shall be connected to ground in a manner that will
retain the ground connection when the product is
unplugged from the receptacle.
The connection to ground of the supplementary
equipment grounding conductor shall be in compliance
with the rules for terminating bonding jumpers at Part K
or Article 250 of the National Electrical Code, ANSI/
NFPA 70.
Termination of the supplementary equipment grounding
conductor is permitted to be made to building steel, to a
metal electrical raceway system, or to any grounded item
that is permanently and reliably connected to the
electrical service equipment ground.
The supplemental grounding conductor shall be
connected to he equipment using a number 8 ring
terminal.
The terminal should be fastened to the grounding lug
provided on the rear panel of the equipment.
The ring terminal should be installed using the
appropriate crimping tool (AMP P/N 59250 T-EAD
Crimping Tool or equivalent).
Do not use this product near water, such as in a wet base-
ment.
For DC-powered devices, the supply power for the product
shall be installed near the equipment and shall be easily acces-
sible.