User manual
Chapter 8. Remote/Management Menus
61202156L1-1 TDU 120e User Manual 8-3
Table 8-1. Unit Access Commands
Command What it does...
Add New Unit
Adds a new device to the table.
You must enter a device unit ID, passcode, unit
type, and polled flag. Unit type can be:
Standard
(which supports any TSU/TDU Multi-
plexer and the ISU 512), or
TSU Standalone
(a single port TSU with no option
card slot).
A passcode of 0 to 9999 for each device or
DEFAULT may be selected, which results in the
default passcode being used (defined as 0022 in
Figure 8-1).
Traps are normally sent from the unit in alarm to
the TDU 120e. For units in the Unit Access Table
that are not chained directly to the TDU 120e but
are managed over Inband or the FDL, traps are not
automatically forwarded. Polling must be enabled
on the TDU 120e for these units in order to receive
Traps on the NMS. The TDU 120e can be config-
ured to poll selected units for traps by enabling the
polled option when adding or modifying a unit
entry.
Modify Unit
Allows unit ID, passcode, device type, and polled
flag to be changed for an existing entry in the table.
Delete Unit
Deletes an entry in the table.
Default Unit Passcode
Sets the default passcode for all devices in the
table that have passcodes set to DEFAULT, or for
any unit not listed in the table.
OK
Returns to the C
ONFIGURE
A
GENT
menu.