User manual

ADT-HC4500 CNC Flame/Plasma Controller
89
ZDR-
XDR-
5V-
ZDR+
5V-
XDR+
YDR-
XPU-
PU_COM
XS3
8
15
7
14
6
13
5
12
4
11
3
10
2
9
1
ZPU+
ZPU-
XPU+
YDR+
YPU-
YPU+
Line S/N Name Function
1 XDR+ X direction signal +
9 XDR- X direction signal -
2 XPU+ X pulse signal +
10 XPU- X pulse signal -
3 YDR+ Y direction signal +
11 YDR- Y direction signal -
4 YPU+ Y pulse signal +
12 YPU- Y pulse signal -
5 ZDR+ Z direction signal +
13 ZDR- Z direction signal -
6 ZPU+ Z pulse signal +
14 ZPU- Z pulse signal -
7 PU_COM Internal 5V positive, not allowed to connect the external
power supply (for driver with single-end input)
15 5V- Internal 5V negative, not allowed to connect the external
power supply
8 5V- Internal 5V negative, not allowed to connect the external
power supply