User manual
ADT-HC4500 CNC Flame/Plasma Controller
74
Use [↑] or [↓] to move the cursor to “B. BIOS”, and press [ENTER]. Then, move the cursor to “2.
Upgrade PRG” with the same method and press [ENTER] again, the system will give a prompt “Do you really
want to upgrade the program, Y/N?” press [ENTER] to confirm. After that, the system will prompt the files
are found and are refreshing. As the upgrade completes, the system will prompt “Upgrade complete, please
restart the machine”. Shut the power supply and restart the controller.
After the upgrade, you should check whether the starting mode is “Normal boot”, as the following picture
shows:
6.6.3 Starting mode
Use [Y+] or [Y-] to move the cursor to “E. Starting mode” and press [ENTER], if the highlight
area is not “Normal start”, you should move it to “Normal start” and then press [ENTER].
6.7 Upgrade in BIOS interface via PC
Decompress the compressed files of client programs in computer.
Connect one end of the connecting wire to computer, and the other end to control system.
First, cut the power supply of controller, and then press and hold the [ESC] key on panel to
connect the power supply, the interface will ask you to input the password, as follows: