User manual
ADT-HC4500 CNC Flame/Plasma Controller
62
4.6 Save
You should press [F6] once every time when the value of a submenu in “Parameter” is modified; otherwise,
the modified value would not be saved.
5. Diagnosis (Diag)
Press [F5] in main interface, and the system will enter the diagnosis interface as Picture 2.6 below:
Picture 5 Diagnosis interface
5.1 Sub-menu
1) Diagnosis interface
In diagnosis interface as Picture 5, press [F1] to enter the diagnosis testing interface as Picture
5.1.1:
Operating instructions:
[F1]: Test the positive rotation of X axis
[F2]: Test the contrarotation of X axis
[F3]: Test the positive rotation of Y axis
[F4]: Test the contrarotation of Y axis
[F5]: Stop the current X/Y rotation
You can press [X+], [X-], [Y+], or [Y-] to move the output cursor, and then press OK to output
the relevant switching signal.
If there is an input signal, a ‘*’ will show below the relevant pin sign of input diagnosis.