User manual
ADT-HC4500 CNC Flame/Plasma Controller
53
3.2.3 Save
3.2.1.3 Saving file
When the processing code is entered or the code is tested, you should press [F3] to save it before exiting
the interface; otherwise, the system cannot memorize the current processing file. Press [F3] and the system
will ask whether to save as other file (as Picture 3.2.1.3). If you press CANCEL], the system will cover the
original file. If you press [ENTER], the system will ask you to input the file name. Once you have entered the
name, press [F5] to save the file.
If there is no need to save the current file, you can press [
] or [ ] to return to the main interface.
3.2.4 New/Delete line
New line: During the editing, you can press [F4] or [ENTER] to add a line of code under the cursor.
Delete line: During the editing, you can press [F5] to delete the code line where the cursor is located.
3.3 Basic operations
1) Keys on panel are divided into two categories, composite key and single function key. Generally, you
are entering the value of lower shift when you press the composite key. If you press [Shift] first and
then a composite key, it becomes the upper shift key. This function is only available in program
editing state.
2) When the cursor is moving up/down, the cursor is located at the end of program automatically. It
moves a line each time you press it.
3) Page Up/Down: You can press [Pagup / S↑] or [Pagdn / S↓] to page up or down.
4) The line number in processing program is generated automatically.
5) You can press [DEL] key on panel to delete a character of instruction where current cursor is located.
6) You can press [INS] on panel to insert a space in the middle of a line.