User manual
ADT-HC4500 CNC Flame/Plasma Controller
49
(Copy) or [ENTER]. After the copy, the system will pop up a prompt “Data are completely copied, press any
key to return”, you can then press any key to exit.
3.1.4 Define
3.1.4 Definition interface
As Picture 3.1 shows, in editing interface, press [F4] (Define) to enter the definition interface.
3) In this interface, press [F1] to define the M07 instruction. The system default M07 perforating
instruction is as follows:
Flame:
c Ignition Fixed Cycle, M52
d Cutting gun falling (Fixed Cycle), M71
e Preheating on (Fixed Cycle), M74
f Perforating cutting gun rising (Fixed Cycle), M72
g Cutting oxygen on, M12
h Perforating cutting gun falling (Fixed Cycle), M73
Plasma:
A. With height-adjusting system:
c Enable M22
d Arcing M12
e Waiting for arc voltage detection signal (IN0)
After arcing, the height-adjusting control starts performing initial location (With initial
location function); perforating and perforating delay automatically, and gives a signal of
successful arc voltage detection to the controller.
B. Without height-adjusting system: