Programming instructions
ADT-CNC4620 Programming Manual
III
Precautions
※Transportation and storage
The packaging boxes shouldn’t be stacked more than six layers
Do not climb onto, stand on or put heavy objects on the packaging box
Do not drag or convey the product with a cable connected to the product
Do not impact or scratch the panel and display
Keep the packaging box away from moisture, insulation and rain
※Unpacking and checking
Unpack and check whether the product is the one you ordered
Check whether the product is damaged during transporting
Check whether the parts are complete and intact according to the packing list
If the model doesn’t match, any accessories are missing or damaged, please contact us immediately
※Wire connection
The personnel for wire connection and checking should be qualified
The product must be grounded reliably (resistance < 4Ω) and do not use neutral wire to replace the earth wire
The wires must be connected properly and firmly to avoid failures and accidents
The surge absorption diode must be connected to the product properly, or else it will damage the product
Please cut off the power supply before inserting/removing the plug or opening the enclosure
※Checking and repairing
Please cut off the power supply before repairing or replacing the components
Check the failure if short circuit or overload occurs, and restart after eliminating all failures
Do not connect/cut off the power supply frequently; wait for at least one minute before restarting
※Others
Do not open the enclosure without permission
Please cut off the power supply if it won’t be used for a long time
Prevent dust and iron powder from entering the controller
If non-solid state relay is used for output, please connect freewheeling diode to relay coil in parallel. Check
whether the connected power supply is qualified to avoid burning out the controller
The lifetime of the controller depends on the environment temperature. If the temperature of processing field is
too high, please install cooling fan. The allowable temperature range of the controller is 0℃-60℃
Avoid using in the environment with high temperature, moisture, dust or corrosive gas
Install rubber cushion if the vibration is severe
※Maintenance
Under normal condition (environment: daily average 30 , load rate 80%, running rate 12 hours every d℃ ay),
please perform daily and periodic checking according to the items below.
Daily checking
Daily
Confirm environment temperature, humidity and
dust
Whether there is abnormal vibration or sound
Whether the vent hole is blocked by yarn
Periodic checking
1 year
Whether the fixed parts are loose
Whether the terminal block is damaged