U;PA0,0;SP;PG1;
After generating PLT file, send the PLT file to controller through serial port test software and save it,
and then convert it to processing file. After generating the processing file, you also need to perform certain
settings, for example, gun feeding/retreating, gun opening/closing operation, scaling, offset, etc.
3. Tips for CorelDRAW12
(1) Importing dxf files
After generating dxf files with AutoCAD, please close AutoCAD before importing the dxf to
CorelDRAW, or else the import will fail. Pay attention to the unit while drawing graphs with AutoCAD. If
the unit is millimeter, select “Metric” in Scaling; if the unit is inch, select “Imperial”.
The imported graphs should be placed on the top and right of the lower left corner (as in the figure
below)
(2) Graphs sorting
Right click on the imported graph and select “Cancel all groups” (as in the figure below)