User`s manual
Chapter 3 Function and Operation
3-30
better perforating performance. When multi-level perforation is adopted, this time is the average time of the
multi-level perforation time.
8. Torch up time. The time during which the torch up signal remains valid after completion of each cutting.
9. Torch down time. The time during which the torch down signal remains valid before start of each
cutting.
10. Perforate torch up time. The time during which the torch up signal remains valid in the perforation
process.
11. Perforate torch down time. The time during which the torch down signal remains valid in the perforation
process.
12. Cutting close time. The time during which the cutting control signal remains valid after completion of
each cutting. It is generally set to zero.
13. Venting time. The time for the torch to pause and output discharging signal after completion of each
cutting.
14. Level-1, Level-2 and Level-3 perforation time setting.
15. Lock gas. Whether to open the gas during preheat.
16. Keep preheat in cut process. Whether or not to enable preheating while cutting.
17. Multi-level perforation. Whether or not to adopt multi-level perforation. This function is usually adopted
while cutting the thick plate and if there is low preheating device in the system. While cutting thin plates, ordinary
perforation is enough; if no low preheating device is available, please don’t adopt this function.
18. Multi-level perforation set. When multi-level perforation is adopted, the multi-level method should be
adopted accordingly. The ascending means to increase one by one, and switching means to switch output of
different levels.
19. Use Capacitive THC. Weather using capacitive THC
20. Continue to cutting if open high preheat or not, after Puase:When low preheat and high preheat are
needed, continue to open high preheat after puase.
To set the parameters on the right, press F1 and then press Tab to switch among different parameters and
move the cursor to the parameter you want to modify. After setting, save the modified parameter.
Plasma