Instruction Manual
VMT6008 22
©ads‐tecGmbH•Raiffeisenstr.14•70771Leinfelden‐Echterdingen
6 Interfaces
6.1 InterfaceSetup
Interface IRQ Adress
COM1 4 3F8h
RFID(Touch) 3 2F8h
Pos: 26 /Datentechnik/ Schnittstellen/ Spannungsversorgung/ Spannungsversor gung für VMT60xx-Seri e @ 2\mod_1260450284020_6. doc @ 6853 @
6.2 24VDCPowerSupply
Thesupplyvoltageisprovidedviaalead‐throughterminalincludingascrewconnection(PhoenixContact
COMBICONMC1,5/4‐STF3.81).(Thefigureshowsthesocketinsidethedevice)
Pin‐Number Signal‐Name
1 PE
2 0VDC
3 Ignitioncontact
4 24VDC
Voltagetolerance
•Inputvoltage:24VDC±20%.
Currentconsumption
Thecurrentconsumptionofthisdevicedependsontheequipmentversion
(e.g.ifaheaterorWLAN,etc.isinstalled.)
• Switch‐oncurrent:7A(1ms)
• Standbycurrentconsumption:0.25mA
• Regularoperation:1.3Awithoutheater
(withoutanyadditionalloadontheUSBportsandwithoutdeliveringthe+5Vsupplyforthesc
anner)
Note:
Thepowersupplycanbeprotectedwithaslow‐blowfuseofupto4A.
Note:
Thetypicalpowerconsumptionofthisdeviceisindicatedinthe"Technicaldetails"
chapter.