1.4 ENVIRONMENTAL CONDITIONS
The device may be operated under the following conditions. Failure to observe these
specifications will terminate any warranty for this device. Ads-tec cannot be held liable for
any damages arising due to improper use and handling.
Temperature for devices including a HDD / Compact Flash:
In operation -20 … 45° C
For storage -20 … 60° C
Temperature for devices including a heater (only CF-Devices)
In operation -25 … 45° C
For storage -25 … 60° C
Humidity:
In operation 10 … 85% without condensate
For storage 10 … 85% without condensate
Vibrations:
In operation 1 G, 10 … 500 Hz
(EN 60068-2-6)
Shock resistance:
In operation 5 G, with a half-wave of 30 ms duration
(EN 60068-2-27)
Broadband noise MIL-STD-810F Method 514.5 figure 514.5 C1
(EN 60068-2-64)
Pos: 8 /Datentechnik/ Allgemeine Hinweise/ Normen/Normen @ 1\mod_121 9145812377_681.doc @ 3946 @