Version 2.
Industrial PCs OPC5012 Product Portfolio Copyright © ads-tec GmbH Raiffeisenstr.14 D-70771 Leinfelden-Echterdingen Germany 2 © ads-tec GmbH • Raiffeisenstr.
Industrial PCs OPC5012 INDEX 1 REMARKS ............................................................................................................................... 5 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2 SAFETY INFORMATION .......................................................................................................... 8 2.1 2.2 2.3 2.4 2.5 3 SYS LED (TWO COLORS) ............................................................................................................. 17 INTERFACES ...
Industrial PCs OPC5012 8.1 8.2 8.3 9 INSTALLING THE OPERATING SYSTEM ............................................................................................... 22 TOUCH SCREEN DRIVER INSTALLATION (WINDOWS 2000/XP) ............................................................... 23 SOFTWARE KEYBOARD ................................................................................................................. 23 TECHNICAL DETAILS .......................................................................
Industrial PCs OPC5012 1 REMARKS 1.1 RELEVANT DEVICE DOCUMENTATION Consult the following documentation for information pertaining to device setup and operation: User manual on the service CD (this documentation): Contains information pertaining to device mounting, startup and operation as well as the technical data for the device hardware. Service CD: Contains drivers, user manual and installation instructions for installing drivers, calibration and using the touch screen. 1.
Industrial PCs OPC5012 1.5 COPYRIGHT This manual and any illustrations contained therein are copyrighted. Any use of this manual which deviates from the copyright stipulations is prohibited. Reproduction, translation and/or electronic and photographic archiving and modification require written permission from ads-tec GmbH. The violation of these rights will be prosecuted. 1.6 AMBIENT CONDITIONS The device can be operated in the following ambient conditions.
Industrial PCs OPC5012 1.7 STANDARDS The device meets the requirements and objectives of the following EC directives: • • The device complies with the test specifications for the CE label according to the European test standards EN 55022 and EN 50082-2. The device complies with the test specifications DIN EN 60950 (VDE 0805, IEC 950) "Safety of Information Technology Equipment". • The device complies with the DIN EN 60068-2-6 (sinusoidal vibration) test specifications.
Industrial PCs OPC5012 2 SAFETY INFORMATION The device is electrically charged and contains highly sensitive components. Permissible modification by the user is limited to installing add-on cards. The manufacturer or a service provider authorized by the manufacturer should be consulted if any other modifications are to be carried out. Whenever such modifications are carried out the device must first be switched off and the power cable must be disconnected.
Industrial PCs OPC5012 2.2 DAMAGE DUE TO IMPROPER USAGE If the control system shows obvious damage caused by incorrect operational and/or storage conditions or improper handling, then the device is to be shut down immediately and protected against unintentional startup. 2.3 WARRANTY AND REPAIRS During the warranty period, repairs may only be carried out by the manufacturer or persons authorized by the manufacturer. 2.
Industrial PCs OPC5012 3 MOUNTING 3.1 MOUNTING OPTIONS The device is intended for installation in control panels and cabinet doors. The control panels and consoles should be accessible from the back for mounting and operation (plug connectors). The device can be installed in control cabinets with wall thicknesses of 2...7 mm. We recommend at least 3 mm for proper mounting with front IP65 protection.
Industrial PCs OPC5012 3.3 MOUNTING PROCEDURE • Cut out the section or the control panel or cabinet door as shown in the illustration. • Slide the device into the cutout from the front (place the ON/OFF switch of an OPC with 24 V DC to the center position). • Insert the fastening bolts with slot nuts in the matching slots in the sheet metal cover and then tighten the screws on all bolts equally (max. torque 25 Ncm) until the faceplate is pulled into place in the cutout.
Industrial PCs OPC5012 4 STARTUP Warning: The PC should be switched off before disconnecting plugs in order to avoid damage to electronic components! In order to avoid formation of condensation, the device should only be switched on once it has acclimated to the room temperature. Pay attention to the voltage permitted for the device. You should allow five seconds to pass between switching the device off and switching it back on. 4.
Industrial PCs OPC5012 4.2 CABLE INSTALLATION The device interfaces and power supply plug are found on the side or the back of the casing. Care should be taken not to damage the pins when connecting the plugs. 4.3 4.4 STARTUP PROCEDURE • For 24 V DC device: Place the cable end sleeves of the power cable wires in the terminals. • Connect the cable for serial / parallel data transfer and fasten the plugs to the sockets. • Connect all further required cables and secure against slippage.
Industrial PCs OPC5012 5 OPERATION 5.1 FRONT CONTROL BUTTONS Depending on the device model, factory settings will include an operating system (Windows CE.net, Windows XP embedded or Windows XP Professional) and a software keyboard. The buttons on the front have already been assigned the following functions in the software keyboard by a special driver: Level 1: Displaying and closing the software keyboard to enter characters via the touch screen.
Industrial PCs OPC5012 5.2 SOFTWARE KEYBOARD If the factory settings include the operating system, then the software keyboard will be installed as well. If the factory settings do not include the operating system, then the software keyboard still has to be installed. The software keyboard can be used to enter data using the touch screen as you would with an external keyboard. Operating the software keyboard version 3.
Industrial PCs OPC5012 5.3 EXTERNAL KEYBOARD The control system has a 6-pin PS/2 connector labeled "keyboard". Standard AT compatible keyboards with the appropriate plugs can be connected here. Proper functioning of a keyboard is to be tested before use. Note: Cherry keyboards are preferred because the timing of the integrated controller is tuned to these devices. While the software keyboard is displayed on the screen, the external keyboard function is limited.
Industrial PCs OPC5012 6 STATUS INDICATORS 6.1 SYS LED (TWO COLORS) Various different device states are displayed by the color and flashing patterns of the SYS LED. The following signals are indicated: • • • LED green LED orange LED off © ads-tec GmbH • Raiffeisenstr.14 • 70771 Leinfelden-Echterdingen Device is on (power on). The switch for changing the display setting is pressed. The device is off. (power off).
Industrial PCs OPC5012 7 INTERFACES 7.1 INTERFACE CONFIGURA ATION INTERFACE COM1 LPT 7.2 IRQ 4 7 ADDRESS 3F8h 378h INTERFACE ASSIGNMEN NT The interfaces are fo ound on the back of the casing. All interfaces are e labeled. The lead out terminal for the pow wer supply is also found on the back of the control system. Note: When using the embedded operating system Windows CE.net et, the communication U etc.
Industrial PCs OPC5012 7.5 NETWORK CONNECTION (RJ45) If the required drivers are installed on the device, the control system can be integrated in an Ethernet network with 10/100 Mbit support using the Ethernet 10/100BaseT network connector and a suitable network cable. The specifications of the underlying network topology are to be adhered to. The drivers required to use this function can be installed from the provided service CD if needed. 1 7.
Industrial PCs OPC5012 7.9 DVI INTERFACE The DVI Interface iss used to transfer analog video signals. It is possible to connect a VGA display by using a su uitable DVI-VGA adapter. Note: The Interface of the t Panel PC works like a DVI-A Interface. transferred analog. g.
Industrial PCs OPC5012 7.10 HARD DRIVE / COMPAC CTFLASH (IDE INTERFACE) The choice of storag ge media depends on individual customer requirrements. The following storage options are available: CompactFlash: his option implements a CompactFlash card with a capacity of at least Th 12 28 MB. The capacity should be chosen depending g on the required op perating system and additional programs to be in nstalled. Hard drive: Th his option implements a 2,5" Festplatte mind. 30 GB G (UDMA).
Industrial PCs OPC5012 8 SOFTWARE/DRIVER INSTALLATION The device is provided with a preinstalled Windows operating system if requested by the customer. The drivers required for this are configured and the operating system is activated by entering the licensing information. If you have to reinstall the operating system, please proceed as follows.
Industrial PCs OPC5012 8.2 TOUCH SCREEN DRIVER INSTALLATION (WINDOWS 2000/XP) Warning: The touch screens in the CPC50XX and OTC50XX devices are connected to the internal USB interface. The required driver has to be installed and the touch screen is automatically recognized by Windows XP. Installation is to be carried out as described in the following: • Switch on and boot the PC • Click on "Start => Run => Browse..." and select the path to the drivers that have been copied to the hard drive (e.g.
Industrial PCs OPC5012 9 TECHNICAL DETAILS 9.1 9.2 DISPLAY DATEN Display 12.1", 800 x 600 Pixel Displayable colors max. 256k. colors TouchScreen Resistive industrial touch screen COMPUTER TECHNICAL DATA The device can be furnished with the following adsX modules (depending on customer requirements). 9.3 24 Version 1 Pentium M 1.1 GHz 256MB - 2GB DDR RAM Intel 855 GME Version 2 Celeron M 1.
Industrial PCs OPC5012 10 SERVICE AND SUPPORT ads-tec and its partners provide customers a comprehensive range of services and a competent support team for quick response to all questions concerning ads-tec products and assemblies. ads-tec devices are also deployed by partner companies and can therefore be customized to meet individual customer needs. Only the system manufacturer can respond to questions pertaining to special configurations and software installations in each case.