User Manual
Communication  4-21 
Connecting completed telephone cable to TELCO/EXT ANTENNA port on 
monitor 
Wiring the Telephone Cable to the Lightning 
Protection Module 
Next, wire the telephone cable to the lightning protection module 
(ADS p/n 103313A) in the following way: 
1.  Open the front cover of the lighting protection module, and 
remove the nuts, washers, and card from the posts inside the 
module. Leave only the bottom-most nut on each post. 
2.  Slice a hole in the grommet in the bottom of the module, and 
run the telephone cable up through the grommet into the 
module. 
3.  Place the lugs for the following wires onto the designated posts, 
and then replace a washer and nut onto each post: 
 Red wire to Telco network interface  Top left post (tip) 
 Green wire to Telco network interface  Bottom left post 
(ring) 