Outputs
Alarm
One per channel
Local Comms
19,200 baud
Data Collection
All data / data since last reading / designated date range
Logging
Types
Count
Modes
Cyclical / designated time period / stop when memory is
full
Capacity
128 Kbytes (approximately 1 year at 15 minutes per
channel)
Interval
1 second to 24 hours
Features
Independent logging per channel
Power
Lithium Battery
Design life 5 years (see note on page 2)
Factory or agent replaceable
(Calculation is based on a 15-minute logging interval.
More frequent measurement intervals may reduce
battery life.)
Battery options
Alkaline field-replaceable battery
Physical
Sealing
IP68 - all models
Operational Range
32°F to 122°F (0°C to 50°C)
Dimensions
Submersible
(No Modem)
4.41 x 2.32 x 6.10 inches (112 x 59 x 155 mm) – all
except 4 channel model
4.41 x 2.32 x 7.01 inches (112 x 59 x 178 mm) – only 4-
channel model