A P P E N D I X B
Parameter Tree
This chapter contains diagrams outlining the structure and content of each item
(heading) contained in the main menu of the Portable FlowShark Pulse transmitter
display. These diagrams can assist you in identifying the location for setting specific
options and parameters on submenus throughout the display menu.
Operation Mode Menu (RUN)
RUN
standard representation of readings
graphic velocity profile graph
day values
info 7 day totalisers plus resettable overall totaliser
interval set totalising time
memory erase? erases internal memory
errors error message memory
trend
flow rate logging function, selected parameter will be indicated
velocity indicated as automatically scaled bar, 90 rows of pixels total
level to scroll within up to 14 days using any arrow key
set storage interval under storage cycle