Manual

D-8 IETG FlowHawk Manual
Note: The entities available are based on the sensors used
and the data logged. In addition, all values are floating
point, unless otherwise defined.
Register Addresses for Entity Data
The following table contains the entities currently available for
output and the associated register addresses. The register addresses
for the quality values corresponding to the current data display in
parentheses.
Description Profile Entity Standard Units of
Measure
Registers
Peak Velocity
from Peak
Combo Sensor
PEAKVEL_1 Meters Per Second 40000-40001
(40064-40065)
Upward
Ultrasonic Depth
from Peak
Combo Sensor
UPDEPTH_1 Millimeters 40002-40003
(40066-40067)
Pressure Depth
from Peak
Combo Sensor
PDEPTH_1 Millimeters 40004-40005
(40068-40069)
Water
Temperature
from Peak
Combo Sensor
WATERTEMP_1 Celcius 40006-40007
(40070-40071)
Surface Velocity
from Surface
Combo Sensor
SURFACEVEL_3 Meters Per Second 40016-40017
(40080-40081)
Smart Depth
from the Surface
Combo Sensor
SDEPTH_3 Millimeters 40018-40019
(40082-40083)
Pressure Depth
from the Surface
Comb Sensor
PDEPTH_3 Millimeters 40020-40021
(40084-40085)
Air Temperature
from the Surface
Combo Sensor
AIRTEMP_3 Celcius 40022-40023
(40086-40087)