Manual

A-2 IETG FlowHawk Manual
Battery Life
15 months at 15-minute sample rate and weekly
communications
Actual battery life will vary depending on
operating temperature, number of active devices
operated, and frequency of communications.
Connectors
U.S. MIL-C-26482 series 1, for environmental
sealing, with gold-plated contacts and interfacial
seals
Inputs and
Outputs
2 configurable sensor inputs
1 communication connector for direct
interface with a computer or GSM modem
module
Air pressure valve (for testing purposes only)
Memory
832 kilobytes
Data Storage
20 days for 6 entities (Peak Combo Sensor) at a
2-minute sample rateRefer to Calculating the
Total Days of Storage Available below for details
and instructions on calculating the number of
days of data that can be stored in memory for a
specific application.
Approvals
Hazardous Area Approved for use in Class I,
Div. 1, Groups C & D, Zone 0 in US, and Zone 0
in the EU via SIRA/ATEX
Certified under IECEx (International
Electrotechnical Commission Explosion Proof)
Intrinsic Safety standards for use in Zone 0/Class
I, Div. 1, Groups C & D rated hazardous areas.
Calculating the Total Days of Storage Available
This section includes a special equation to use in determining the
number of days of data that can be stored in the monitor memory
based on a specific application. Consider the following when
calculating the total days:
The monitor memory holds 832 kilobytes (or 851,968 bytes) of
data.