User Manual
Sensor Installation and Connection 3-7
Quantity Description ADS Part Num b er
1 IS Doppler Vel ocity Sensor with two 4-40 x
5/16-inch s t ai nl ess s t eel screws
106194A–35 (ft)
as needed IS Vel ocity Sensor Extension Cable 106135A–xxx
2
1 IS Pressure Depth S ensor (0 – 5 psi) wi th t wo
4-40 x 5/16-inch stainless st eel screws
3754-0001–40
3
(ft)
as needed IS Pressure Depth S ens or Extension Cable 106136A–xxx
2
1 replacement dryer tube 3704–0032
1 IS P C Comm uni cation Direc t Connecti on Cable 106228A Rev H5
as needed EMU Serial Cable 3800–0147
15
¼- × 2 ¼-inch stainless steel anchor bolts
I01–0002
1 3/8-inch x 3-inch anchor bolt and nut I01–0003
2 3/8-inch x 1-inch st ai nl ess steel hex bolts I01–0001
4 3/8 – 16 stainless steel hex nuts I15–0002
5 3/8-inch s tainless steel flat washers I55–0001
1 3/8-inch x 2-inch st uds I01–0009
15 plasti c push mounts I01–0006
15 11-inch cabl e ties I05–0003
25 4-inch cable t i es I05–0001
15 8-inch cable t i es I05–0002
15 anchor cable t i es I05–0004
1 stainl es s steel ri ng (sized for pipe)
I25–0081 to 0094
4
1 spreader as s embly I10-0003
1 18-inch st ai nl ess st eel crank handle I10–0012
1
Additional models of the FlowShark IS monitor are also available: 5000-IS1-US
(without internal battery), 5000-IS1 (for EU without internal battery), and 5000-IS1-
01 (for EU, with internal battery).
2
Extension cables can be ordered in specific lengths up to 300 feet. Note the desired
length (in feet) in the xxx portion of the part number. For example, if the application
requires a 50-foot extension cable for an IS ultrasonic sensor, the part number would
be 106137A–050.
3
IS pressure depth sensors are also available in 0–15 psi (p/n 3754–0002–40) and 0–
30 psi (p/n 3754–0003–40).