3-46 ADS FlowShark IS Manual
5. Connect each sensor cable to the appropriate port. Tighten each
connector in a clockwise direction until it clicks into place, and
verify that it is seated correctly.
6. For locations exhibiting the presence of hydrogen sulfide
and/or high moisture, provide added protection by wrapping
the connection with mastic tape.
7. Seal any unused connectors with a cap. If necessary, obtain
additional caps from the regional ADS representative.
Note: An air valve is present in the center of the monitor
top. This valve exists only for testing purposes during the
manufacturing process. Do not attempt to fill the monitor
with a i r or pressurize the mo nitor!
Secur ing the Dr yer Tube to the Monit or
Secure the dryer tube to the monitor in the following way:
1. Attach the dryer tube from the pressure depth sensor in the
vertical position to the monitor handle and chassis bolt using
cable ties.
Securing t he dryer t ube t o the moni tor using c abl e ties
2. Make sure the black end cap on the dryer tube is removed
before installing the monitor in the manhole.